Description
Product Features:
1. Maintenance safety lock: greatly ensuring the personal safety of maintenance personnel;
2. Anti theft cover plate: It can effectively prevent electricity theft, unauthorized pulling of wires, etc;
3. Independent power supply design: can effectively prevent the overall system from being paralyzed and unable to work;
4.1.3 inch OLED display screen design: providing a more intuitive human-machine operation interface for maintenance personnel;
5. Modular design: can be selectively paired and used more flexibly;
6. High accuracy: voltage and current detection accuracy is 0.5 level, and electricity accuracy is 1.0 level;
7. The overall function of the circuit breaker preserves the characteristics of the small circuit breaker;
8. It can flexibly choose communication methods and can also be used as a gateway;
9. Flexible selection of function shutdown, alarm, and trip protection methods;
10. Multiple remote upgrade modes, allowing users to upgrade and maintain without any hassle;
11. Power outage protection design: After the main circuit is powered off, it ensures that data is saved and uploaded without loss;
12. Automatic judgment and analysis of fault causes and operational events, displaying logs for easy maintenance and troubleshooting;
13. Timing switch function: ensuring equipment timing switch, ensuring energy consumption, and saving electricity;
14. The function of load imbalance, phase loss, phase mismatch, and over temperature protection greatly ensures the aging of equipment and lines, and ensures the safety of electricity consumption;
15. The leakage protection is sensitive, and different leakage protection values can be set according to the usage environment.
Product installation precautions:
1. Reverse connection of product inlet and outlet lines is absolutely not allowed;
2. After installing the product, check if the wiring is correct? Pay special attention not to connect N and PE incorrectly; 3. The leakage function of GYRC-ZN01-PE product is not allowed to be turned off. Set the leakage parameter value to 30mA (recommended), which can be set to 30mA according to actual application scenarios;
4. For online products, please download and install the APP and scan the QR code on the product;
5. This product is equipped with a standard communication port RS 485, which can be connected to computers and various communication devices through RS 485 to USB converters to achieve information exchange and control;
6. The default baud rate of the device is 3840 0b ps, which can be viewed and set in the communication menu;The 7.4G version of the product requires the insertion of an SI M card before use in order to achieve remote information exchange control;
8. Product installation and debugging must be carried out by professional electricians;
9. This product can be customized according to user needs. Please contact relevant technical personnel for details;
10. For special purposes, please consult the manufacturer and service hotline;
Function Description | ||||
Product Model | BYRC-ZN01-100AP-2P | BYRC-ZN01-100AP-4P | GYRC-ZNO1-PE-2P | GYRC-ZN01-PE-4P |
Is the Pe line properly connected to the alarm | nothing | nothing | Local sound and light alarm+remote | Local sound and light alarm+remote |
Load immersion alarm | nothing | nothing | Local sound and light alarm+remote | Local sound and light alarm+remote |
Current setting | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Overload delay protection | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Residual operating current | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Overvoltage protection delay | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Overvoltage protection value | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Overvoltage function | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Undervoltage protection value | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Undervoltage protection delay | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Under voltage function | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Over temperature protection value | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Overtemperature protection delay | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Over temperature protection function | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Power limit value | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Power limiting delay | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Power limiting function | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote | Local Settings+Remote |
Phase loss protection function | nothing | have | nothing | have |
Electricity metering | have | have | have | have |