GYM10 DC 4.5KA 4P DC MCB

The GEYA GYM10 DC 4P Mini Circuit Breaker (MCB) is engineered for superior performance in DC applications, offering robust protection against overloads, short circuits, and reliable isolation. Designed for photovoltaic systems, communication setups, and other DC environments, this MCB ensures safety, durability, and seamless integration into your projects.

  • Standards: IEC/EN60947-2, GB/T 14048.2

  • Rated Current (In): 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A

  • Rated Voltage (Ue): 1000VDC (4P)

  • Tripping Curves:

    • Type C: li = 8.5In

    • Type D: li = 12In

  • Breaking Capacity: 4500A

  • Poles: 4P

  • Rated Insulation Voltage (Ui): 500V

  • Rated Impulse Withstand Voltage (Uimp): 4kV

→ Download GYM10 DC 4P Mini Circuit Breaker Catalog

→ Download GYM10 Series INMETRO Certification for Brazil Market 

Description

GYM10(4P) DC MCB Highlight:

  • Advanced Protection: Safeguards against overloads and short circuits, ensuring system reliability in demanding DC applications.

  • Contact Position Indication: Easily monitor the breaker’s status for enhanced operational safety.

  • High Wiring Capacity: Supports up to 25 mm² wiring, providing flexibility for various installations.

  • Versatile Voltage Rating: Rated at 1000VDC for 4-pole configurations, ideal for high-voltage DC systems.

  • Durable Design: Boasts a mechanical life of 20,000 cycles, ensuring long-term reliability.

  • Temperature Compensation: Adapts to ambient temperatures from -20°C to 60°C with precise current correction factors for consistent performance.

Temperature Compensation:

When the ambient temperature is not the baseline temperature of 30℃,the reference correction coefficient is as follows:

Ambient Temperature -20℃ -10℃ 0℃ 10℃ 20℃ 30℃ 40℃ 50℃ 60℃
Current Correction Factor 1.25 1.2 1.15 1.10 1.05 1.00 0.95 0.90 0.85

 

Outline Overall and Installing Dimensions:

Outline Overall and Installing Dimensions

Wiring Diagram of GYM10 DC 4.5KA 4P:

wiring diagram

Technical Specification
Standard IEC/EN60947-2、GB/T 14048.2
rated Current(In) 6、10,16、20、25、32、40、50、63A
Rated Voltage(Ue) 1P:250VDC;2P:500VDC; 3P;750VDC;4P:1000VDC;
Tripping Curves li=8.5In(Trip type C),li=12In(Trip type D)
Breaking Capacity 4500A
Poles 1P、2P、3P、4P
mechanical Life 20000 time
rated insulation voltage (Ui) 500V
rated impulse withstand voltage (Uimp) 4kV

Click Here To Download The GYM10 Series INMETRO Certification

INMETRO: The GYM10 Series MCB has passed INMETRO’s rigorous testing. This certification guarantees that our GYM10 MCB complies with the safety and performance regulations of the Brazilian market, providing customers with reliable and safe MCB products.

In same series: GYM10 DC-4KA-1P, GYM10 DC-4KA-2P, GYM10 DC-4KA-3P

Contact Us
Contact Us

Check Out The Full Catalog

Quick Info Exchange Helps Us Serve You Better
(Low-voltage and solar energy electrical components catalog)

Electrical Equipment catalog