GY-SVG-PLUS High-Spec Static Var Generator

GY-SVG-PLUS is a high-configuration Static Var Generator (SVG / STATCOM) that delivers real-time reactive power compensation, three-phase unbalance correction and neutral zero-sequence current filtering — built on a DSP + CPLD three-level digital control core for industrial-grade power quality.

  • Transient response < 50 µs · full response < 10 ms — no over/under-compensation
  • Reactive compensation rate ≥ 99% · power factor corrected to ≥ 0.99
  • 3-phase unbalance compensation — residual unbalance ≤ 5%
  • Neutral-line zero-sequence filtering = 3× phase line current
  • 2× external CT channels — supports HV-side / LV-side sampling and component compensation
  • Modular & parallel-ready — wall-mount or rack-mount, small footprint
  • EMC Class A (RE & CE) — independent air ducts & isolated PCB compartments
SKU GY-SVG-PLUS Category

Description

GY-SVG series application diagram

The GY-SVG-PLUS High-Spec Static Var Generator is a high-configuration SVG / STATCOM module that connects a voltage source converter (VSC) to the grid through an LCL filter to deliver dynamic reactive power compensation, three-phase unbalance correction, power-factor correction to ≥ 0.99 and neutral-line zero-sequence current filtering — with a transient response under 50 µs and full response under 10 ms, ideal for industrial plants, EV charging, renewable energy and commercial distribution systems.

GY-SVG-PLUS — Overview

GY-SVG-PLUS is the high-spec member of GEYA’s GY-SVG family. Compared with the standard GY-SVG and the single-phase GY-SVG-5k/2L, the PLUS model adds two external CT sampling channels, stronger neutral zero-sequence current filtering (3× phase current), optimised EMC capacitive performance and improved stability.

Working Principle

The GY-SVG-PLUS connects a voltage source converter (VSC) to the power grid in parallel through an LCL filter. By precisely adjusting the amplitude and phase of the converter’s AC-side output voltage, the device dynamically and accurately compensates reactive power in the grid system. The transient response time is under 50 µs and the full response time is under 10 ms, completely avoiding over-compensation and under-compensation. The neutral-line zero-sequence current filtering capability reaches three times the phase line current, while the EMC capacitive performance and overall stability are further enhanced.

Form Factors

Wall-Mounted Module

Top cable entry, built-in HMI — saves floor space, ideal for commercial buildings and distributed installations.

Rack-Mounted Module

Rear cable entry, optimised for cabinet integration and parallel stacking in industrial switchgear rooms.

Key Performance Highlights

Full-Digital Control Core

DSP + CPLD architecture, three-level topology, advanced reactive-power detection algorithm and PWM control strategy.

Modular & Parallel-Ready

Multiple modules can be paralleled for higher capacity — small footprint and easy maintenance.

Independent Air Ducts

Independent air ducts and isolated PCB compartments ensure long-term stable operation in dusty / warm environments.

Dual External CT Channels

Two current sampling channels — supports LV-side / HV-side sampling and reactive-component compensation strategies.

Selectable Compensation Modes

Reactive only, or reactive + 3-phase unbalance compensation — selectable on the HMI.

High Compensation Accuracy

Reactive power compensation rate ≥ 99%; unbalance degree after compensation ≤ 5%.

Neutral Zero-Sequence Filtering

Neutral-line zero-sequence current filtering capability is 3× the phase line current — excellent for 3P4W loads.

Millisecond-Level Response

Transient < 50 µs, full response < 10 ms — precise compensation for impact reactive loads.

EMC Class A

RE & CE items both meet Class A test standards — suitable for sensitive installations.

Typical Applications

  • Industrial plants with welders, cranes & arc furnaces
  • EV charging stations & depots
  • Wind & solar PV plant grid-tie support
  • Data centers & telecom rooms
  • Hospitals & medical imaging facilities
  • Commercial bus risers & lighting feeders
  • Metallurgy, mining & rail transit
  • Oil & gas processing sites

Why Choose the GY-SVG-PLUS

  • Power factor improved to ≥ 0.99 — eliminates utility low-PF penalties.
  • Reduces line losses, transformer heating and nuisance breaker trips.
  • Solves three-phase unbalance and neutral over-current issues in 3P4W systems.
  • Stepless, bidirectional compensation — no resonance, no over-compensation, no contactor wear.
  • EMC Class A certified — safe alongside sensitive electronics.
  • Plug-in modular maintenance with minimal downtime.

Installation Guidelines

  • Connection: The SVG is installed in parallel with the load — load current does not flow through the unit.
  • Wiring: Suitable for 3P3W and 3P4W grids; confirm grid voltage and configuration before energising.
  • Current Transformers: Two external CT channels available — confirm CT polarity and ratio in the HMI before commissioning.
  • Ventilation: Maintain clearance around the air inlet / outlet; cooling is forced air with independent ducts. Ambient -10 °C to +50 °C (derate above 40 °C).
  • Altitude: Derate capacity per GB/T 3859.2 above 2000 m.
  • Cable entry: Top entry for wall-mount, rear entry for rack-mount.
  • Grounding: Reliable PE grounding is mandatory for EMC performance and personnel safety.
  • Parallel operation: Ensure consistent CT signal distribution and matching firmware versions when paralleling modules.
  • Commissioning: Select the compensation mode (reactive only / reactive + unbalance), target power factor and protection thresholds on the HMI before energising the load.
  • Maintenance: Periodically clean the air filter; modules are plug-in replaceable to minimise downtime.

GY-SVG-PLUS Technical Specifications

Available in 220V (37 kvar / 50 kvar) and 380V (75 kvar / 100 kvar) variants. All other parameters are shared across the range.

Parameter Specification
Model GY-SVG-PLUS-220V  |  GY-SVG-PLUS-380V
Altitude < 2000 m; above 2000 m, derate according to GB/T 3859.2
Ambient Temperature -10 °C ~ +50 °C (above 40 °C, capacity derating ≤ 30%)
Relative Humidity ≤ 90% RH, no condensation on the surface at a monthly minimum temperature of 25 °C
Pollution Degree ≤ Class III
Operating Voltage 220V model: AC 220 V (-20% ~ +20%)
380V model: AC 380 V (-20% ~ +20%)
Operating Frequency 50 Hz / 60 Hz (45 Hz ~ 63 Hz)
Rated Compensation Capacity 220V model: 37 kvar, 50 kvar
380V model: 75 kvar, 100 kvar
Grid Configuration Three-phase three-wire (3P3W) / Three-phase four-wire (3P4W)
Number of Parallel Units Unlimited
Overall Efficiency ≥ 97%
Switching Frequency 16 kHz
Function Selection Reactive power compensation / Reactive power compensation + three-phase unbalance compensation
Reactive Compensation Rate Reactive power compensation ≥ 99%
Unbalance Compensation Capability Unbalance degree after compensation ≤ 5%
Full Response Time < 10 ms
Noise Level ≤ 65 dB
Communication Method 2× RS485 communication ports (Wi-Fi supported)
Protection Functions Overload, software/hardware overcurrent, grid overvoltage/undervoltage, grid voltage unbalance, power supply failure, over-temperature, frequency anomaly, short circuit protection, resonance protection, etc.
Overload Capability Rated 1.2× overload for 60 seconds
Installation Method Rack-mounted / Wall-mounted
Cable Entry Rear cable entry (rack-mount) / Top cable entry (wall-mount)
Protection Rating IP20 (IP54 customizable)
Neutral Line Filtering Capability Neutral line filtering capacity is 3 times that of phase filtering capacity
Cooling Method Forced air cooling
Electromagnetic Compatibility EMC – Radiated Emission (RE) and Conducted Emission (CE) meet Class A test standard

Frequently Asked Questions

1. What is the GY-SVG-PLUS?

GY-SVG-PLUS is the high-spec model of GEYA’s GY-SVG Static Var Generator family. It connects a voltage source converter (VSC) to the grid through an LCL filter and, by adjusting the amplitude and phase of the converter’s AC-side output voltage, dynamically and accurately compensates reactive power, three-phase unbalance and neutral zero-sequence current. It is built on the same DSP + CPLD three-level digital control core as the rest of the GY-SVG family but adds two external CT sampling channels, stronger neutral current filtering and improved EMC for demanding industrial sites.

2. What functions does the GY-SVG-PLUS provide?

  • Reactive power compensation — ≥ 99%, inductive & capacitive, stepless and bidirectional.
  • Power-factor correction — target PF ≥ 0.99.
  • Three-phase unbalance compensation — residual unbalance ≤ 5%.
  • Neutral-line zero-sequence current filtering — up to 3× phase line current.
  • Voltage stabilisation — fast dynamic regulation of bus voltage.
  • Dynamic / impact load compensation — full response < 10 ms.
  • Comprehensive protection — overload, over-current, over- / under-voltage, over-temperature, short-circuit and frequency anomaly.

3. What are the key parameters that affect model selection?

  • Grid configuration: 3P3W or 3P4W — match to site distribution system.
  • Required kvar capacity: determined by total load reactive demand & target power factor; multiple modules can be paralleled.
  • Compensation requirements: reactive only, or reactive + three-phase unbalance.
  • Sampling strategy: two CT channels for LV-side / HV-side sampling or component compensation.
  • Installation environment: ambient temperature, altitude (derate > 2000 m), required IP rating (IP20 standard / IP54 optional).
  • Form factor: rack-mount for switchgear cabinets, wall-mount for distributed installations.

4. What options are currently available?

  • Form factor: Wall-mounted module or Rack-mounted module.
  • Wiring: 3P3W or 3P4W.
  • Function: Reactive compensation only, or reactive + 3-phase unbalance compensation.
  • Protection rating: IP20 standard; IP54 customisable.
  • Communication: 2× RS485 standard, Wi-Fi supported.
  • Parallel expansion: Multiple modules can be paralleled on the same feeder for larger capacity.

5. Which standards does it comply with and which markets is it designed for?

The GY-SVG-PLUS is designed in accordance with international power-quality and EMC standards. Its RE and CE EMC items meet Class A test standards, and altitude derating follows GB/T 3859.2. It also supports compliance with IEC 61000 power-quality requirements and typical utility power-factor / voltage-quality codes. The product is targeted at industrial, commercial and infrastructure markets globally — including manufacturing plants, renewable energy plants, oil & gas, mining, EV charging, healthcare, data centers, telecom and rail transit across Asia-Pacific, EMEA and the Americas.

6. Installation notes & precautions

  • Parallel connection: The SVG is wired in parallel with the load — never in series.
  • Voltage matching: Confirm grid voltage and 3P3W / 3P4W configuration before energising.
  • CT installation: Verify CT polarity and ratio on both sampling channels before start-up.
  • Ventilation: Maintain clearance for the forced-air intakes; ambient -10 °C ~ +50 °C (derate above 40 °C).
  • Altitude: Derate per GB/T 3859.2 above 2000 m.
  • Cable entry: Top entry for wall-mount, rear entry for rack-mount.
  • Grounding: Reliable PE grounding is mandatory for both EMC performance and personnel safety.
  • Commissioning: Configure compensation mode, target power factor and protection thresholds via the HMI or Wi-Fi tool before energising the load.
  • Maintenance: Periodically clean the air filter; modules are plug-in replaceable.