GRV8-4UVS 3 Phase Under Over Voltage Relay

The GEYA GRV8-4UVS is a state-of-the-art 3 phase under over voltage relay designed to protect industrial and commercial equipment from voltage drops and phase-related issues. Engineered for reliability, this relay monitors all three phases to ensure stable operation of motors, HVAC systems, and other critical loads. Its advanced features and compact design make it an essential component for maintaining system integrity and preventing costly downtime.

Rated Voltage:AC 220V / 380V / 400V
Frequency Range:45Hz – 65Hz
Measurement Accuracy:<1%
Under Voltage Range:Adjustable (e.g., 160V – 210V per phase)*
Trip Delay Time:Adjustable (e.g., 0.1s – 10s)*

→ Download GRV8-4UVS Three Phase Under Voltage Relay Catalog PDF

Category

Description

Product Highlight:

Comprehensive 3-Phase Monitoring: Tracks voltage levels across all three phases to detect under voltage and phase anomalies.

Customizable Protection: Adjustable under voltage thresholds and trip delays for tailored system protection.

Wide Frequency Range: Operates seamlessly within 45Hz to 65Hz, suitable for global power standards.

Clear Status Display: LED indicators provide instant feedback on relay operation and system health.

Efficient Installation: Compact 36mm width with DIN rail mounting for easy integration into control panels.

Panel Diagram:

Panel Diagram

Functions Diagram:

Functions Diagram

Wiring Diagram:

Wiring Diagram

Dimensions(mm):

Dimensions

Model GRV8-4UVS Three Phase Under Voltage Relay
Function Under voltage
Monitoring terminials L1-L2-L3-N
Supply terminals L1-N
Rated supply voltage(Un) 220V/230V/240V
Rated supply frequency 45Hz-65Hz
Under voltage threshold S:70%-95%of Un
Trip delay time(Tu) 0.1s
Hysteresis 5V
Measurement error ≤1%
Power on delay time(Td) Adjustable: 5min-15min
Recovery delay time(Tr) Adjustable: 5min-15min
Konb setting accuracy 10% of scale value
Supply indication green LED
Output indication red LED
Output 1×SPDT
Current rating 10A/AC1
Switching voltage 250VAC/24VDC
Mechanical life 1*107
Electrical life(AC1) 1*105
Operating temperature -20℃ to +55℃(-4℉ to 131℉)
Storage temperature -35℃ to +75℃(-22℉ to 158℉)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage category III
Pollution degree 2
Max.cable size(mm²) solid wire max.1*2.5 or 2*1.5/with sleeve max.1*2.5(AWG 12)
Tightening torque 0.8Nm
Dimensions 90×18×64mm
Weight 63g,65g
Standards EN 60255-1,IEC60947-5-1
Contact Us
Contact Us

Check Out The Full Catalog

Quick Info Exchange Helps Us Serve You Better
(Low-voltage and solar energy electrical components catalog)

Electrical Equipment catalog