GRV8-1UVR Single Phase Undervoltage Relay

The GEYA GRV8-1UVR is a single-phase undervoltage relay specifically designed for industrial and commercial applications. It is intended to protect inductive loads, such as air conditioning systems and motors, from damage caused by sudden low voltage fluctuations. Utilizing advanced True RMS measurement technology, this device continuously monitors the supply voltage in real time and promptly disconnects the load when the voltage falls below a preset threshold, effectively preventing equipment damage and production interruptions.

  • Function: Under voltage
  • Rated supply voltage(Un):220V/230V/240V
  • Rated supply frequency:45Hz-65Hz
  • Under voltage threshold:Fixed 75% of Un

→ Download GRV8-1UVR Single Phase Undervoltage RelayCatalog PDF

Category

Description

Applications:

  • Product is used for highly fluctuating inductive load such as Air.
  • Conditioning system inIndustrial and commercial establishments.
  • lt protects the system equipment and load from sudden under voltage fuctuations.

Product Highlight:

  • Reliable Protection: Shields motors, air conditioning systems, and other inductive loads from harmful under voltage conditions.
  • True RMS Measurement: Delivers precise voltage monitoring, even in environments with harmonics or distorted waveforms.
  • Wide Compatibility: Functions across a 45Hz to 65Hz frequency range, adaptable to diverse power systems.
  • High Precision: Offers voltage measurement accuracy of less than 1% for consistent performance.
  • User-Friendly Design: Features an LED status indicator and a compact 1-MODULE format for easy DIN rail mounting.
Item GRV8-1UVR Single Phase Undervoltage Relay
Function Under voltage
Monitoring terminials L-N
Supply terminals L-N
Rated supply voltage(Un) 220V/230V/240V
Rated supply frequency 45Hz-65Hz
Under voltage threshold R:fixed 75% of Un
Trip delay time(Tu) 0.1s
Hysteresis 5V
Measurement error ≤1%
Power on delay time(Td) Adjustable: 5min-15min
Recovery delay time(Tr) Adjustable: 5min-15min
Konb setting accuracy 10% of scale value
Supply indication green LED
Output indication red LED
Output 1×SPDT
Current rating 10A/AC1
Switching voltage 250VAC/24VDC
Mechanical life 1*107
Electrical life(AC1) 1*105
Operating temperature -20℃ to +55℃(-4℉ to 131℉)
Storage temperature -35℃ to +75℃(-22℉ to 158℉)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage category III
Pollution degree 2
Max.Cable size(mm²) solid wire max.1×2.5or 2×1.5/with sleeve max.1×2.5(AWG 12)
Tightening torque 0.8Nm
Dimensions 90×18×64mm
Weight 63g,65g
Standards EN 60255-1,IEC60947-5-1

 