GQRR Automatic Aerosol Fire Extinguishing Device

  • Type range – DIN rail, round, and rectangle GQRR models.
  • Agent weights – 10g, 20g, 30g, 40g, and 50g options.
  • Thermal start – Lead-wire activation temperature is listed as ≥170°C.
  • Fast discharge – Aerosol spraying time is listed as ≤6 seconds.
  • Cabinet sizing – 10g to 40g covers 0.1-0.4 m³.
  • Extinguisher Class: Class A, B, E.

Description

GQRR Hot Aerosol Fire Suppression Device

The GQRR hot aerosol fire suppression device is designed specifically for electrical cabinets, distribution boxes, and compact electrical enclosures that need localized fire suppression. The series includes DIN rail, round, and rectangle structures, with 10g to 50g agent options for different cabinet layouts and protected spaces. Active ingredient content: 80%(Strontium nitrate + potassium nitrate)

Naming Convention

GQRR Model Naming Convention

Working Principle

The device uses a thermal lead-wire activation structure. When the lead wire reaches the activation condition, the unit starts and releases aerosol agent into the protected enclosure. The specified thermal activation temperature is ≥170°C, and the aerosol spraying time is ≤6 seconds.

Key Features

  • Three structure options: DIN rail, round, and rectangle models support different cabinet layouts and mounting requirements.
  • Multiple agent weights: 10g, 20g, 30g, 40g, and 50g options are available across the GQRR range.
  • Cabinet volume matching: the selection data lists 10g for 0.1 m³, 20g for 0.2 m³, 30g for 0.3 m³, and 40g for 0.4 m³.
  • Fifth-generation identification process: the upgraded design replaces conventional adhesive labels with direct AI color printing, helping prevent skewed, peeling, or detached labels while providing a clean, durable appearance.
  • PA66-V0 shell: the specified shell material provides a flame-retardant enclosure for the device body.
  • Wide environmental range: the specified operating temperature is -50°C to 90°C, with relative humidity up to 95% RH.
  • Lead-wire configuration: the standard product uses two 10 cm lead wires, with custom lead lengths available on request.

Protection And Selection

For cabinet fire suppression selection, the agent weight should be matched to the protected enclosure volume. DIN rail models are suitable when the distribution box requires rail mounting, while round and rectangle models can be selected according to the internal space, mounting surface, and component layout.

Installation And Maintenance

Before installation, confirm the cabinet volume, model structure, mounting position, and lead-wire layout. The lead wires should be kept in a reliable position and protected from unnecessary pulling or damage. During cabinet maintenance, check the installation status and replace the device according to the specified agent validity period and applicable local fire safety requirements.

Certification and Global Supply

Supporting documentation includes EU CE documentation, CNAS-accredited test reports, MSDS, international shipping certificates, and quality approval documents. GEYA cabinet fire suppression devices have been supplied to and field-applied in more than 40 countries, providing distributors and project buyers with established documentation support for international procurement.

Applications

GQRR is suitable for distribution boxes, control cabinets, low-voltage panels, and compact electrical enclosures where localized fire suppression is required. For distributors, panel builders, OEM/ODM partners, and engineering buyers, GEYA can support model selection based on cabinet volume, installation layout, and project requirements.

Size Drawing

GQRR standard size picture 2
GQRR standard size picture 3
GQRR standard size picture

Technical Parameters

Parameter Source Value Notes
Series GQRR Hot aerosol fire suppression device
Structure types DIN Rail, Round, Rectangle Select by mounting layout and enclosure space
Agent weight range 10g, 20g, 30g, 40g, 50g DIN Rail models are listed from 10g to 40g
Protected space guide 10g: 0.1 m³; 20g: 0.2 m³; 30g: 0.3 m³; 40g: 0.4 m³ 50g protected space needs confirmation before publishing
Activation mode Thermal activation Lead-wire activation structure
Thermal activation temperature ≥170°C Source workbook value
Spraying time ≤6 seconds Aerosol release time listed in the source workbook
Operating temperature -50°C to 90°C Working environment range
Relative humidity 95% RH Working environment humidity
Agent validity 10 years Replace according to product condition and local requirements
Shell material PA66-V0 Listed as nylon PA66-V0
Color Red Listed in the model remark sheet
Standard lead wire Two 10 cm lead wires, total 20 cm Custom lead length available on request
Oxidizer composition Nitric acid / potassium nitrate 50%-58% Source workbook listing; confirm final SDS wording if required
Packing quantity Inner box: 1 pc; middle box: 10 pcs; outer carton: 100 pcs Source workbook merged value
Product dimensions Need confirmation from dimension images Dimension cells are embedded images in the source workbook

Viscosity: N/A

Model Options

Structure Product Style GEYA Model Agent Weight Unit Weight Package Size (cm) Carton Gross Weight
DIN Rail Guide rail fire extinguishing device GQRR-0.01 2/10D(R) 10g 60g Inner: 10.1*2.1*7.1; middle: 22.5*10.7*7.8; outer: 56.5*24.5*18 7.5kg
GQRR-0.02 2/10D(R) 20g 70g 8.5kg
GQRR-0.03 2/10D(R) 30g 80g 9.5kg
GQRR-0.04 2/10D(R) 40g 81g 10.5kg
Round Circular fire extinguishing device GQRR-0.01 2/10Y(R) 10g 8.5g Inner: 9.2*3.1*9; middle: 32.2*9.6*10; outer: 50.5*33.6*22 10.93kg
GQRR-0.02 2/10Y(R) 20g 9.5g 11.93kg
GQRR-0.03 2/10Y(R) 30g 10.5g 12.93kg
GQRR-0.04 2/10Y(R) 40g 11.5g 13.93kg
GQRR-0.05 2/10Y(R) 50g 12.5g 14.93kg
Rectangle Square fire extinguishing device GQRR-0.01 2/10F(R) 10g 70g 9.35kg
GQRR-0.02 2/10F(R) 20g 80g 10.35kg
GQRR-0.03 2/10F(R) 30g 90g 11.35kg
GQRR-0.04 2/10F(R) 40g 100g 12.35kg
GQRR-0.05 2/10F(R) 50g 110g 13.35kg

Check GQRR Hot Aerosol Fire Suppression Device CE Certificate

Please contact us to obtain detailed CE reports, raw material composition test reports, and certificates of transport conditions.

FAQs

What is the GQRR aerosol fire distinguishing device?

GQRR is a compact hot aerosol fire suppression device for electrical cabinets, distribution boxes, and enclosed electrical equipment. It is available in DIN rail, round, and rectangle structures to match different cabinet layouts.

What is its core function?

Its core function is localized fire suppression inside a protected electrical enclosure. When the thermal lead-wire activation condition is reached, the device starts and releases aerosol agent into the cabinet space.

Which parameters are important for selection?

Protected space: the source table lists 10g for 0.1 m³, 20g for 0.2 m³, 30g for 0.3 m³, and 40g for 0.4 m³.

Mounting structure: choose DIN rail, round, or rectangle according to cabinet layout.

Environment: check operating temperature, humidity, activation temperature, and lead-wire layout before final selection.

Which models and specifications are available?

DIN Rail: GQRR-0.01 2/10D(R), GQRR-0.02 2/10D(R), GQRR-0.03 2/10D(R), and GQRR-0.04 2/10D(R).

Round: GQRR-0.01 2/10Y(R) to GQRR-0.05 2/10Y(R).

Rectangle: GQRR-0.01 2/10F(R) to GQRR-0.05 2/10F(R).

Which standards and target markets does it support?

The supplied workbook does not list certification or standard scope for this model, so any market-specific compliance claim should be confirmed with the latest GEYA certificate file before publishing. The product is intended for B2B electrical cabinet manufacturers, panel builders, distributors, OEM/ODM partners, and engineering buyers.

What should be noted during installation and maintenance?

Confirm the protected cabinet volume, mounting position, lead-wire route, and model structure before installation. Avoid pulling or damaging the lead wires, keep the device in a suitable cabinet position, and replace it according to the listed agent validity period and local fire safety requirements.