Description
GPS6-VA5 Self-Resetting Over/Under Voltage and Current Protector
The GPS6-VA5 self-resetting over/under voltage protector monitors voltage and current in a 2P AC 220V circuit. It combines adjustable overvoltage, undervoltage, and overcurrent protection with a dual LED display and automatic reconnection. Confirmed rated-current options are 40A, 63A, and 80A.
Working Principle
The microcontroller continuously compares the measured voltage and current with the selected protection limits. If a measured value moves outside those limits, the protector disconnects the output. After the supply returns to the permitted range and the configured delay elapses, the unit reconnects automatically. The supplied technical table lists a 0.5-second overvoltage trip delay.
Key Features
- Overvoltage and undervoltage protection: adjustable limits allow the protector to respond to supply voltage outside the selected range.
- Overcurrent protection: current monitoring adds another adjustable protection condition for the connected circuit.
- Automatic reconnection: the output can be restored automatically after the measured values recover and the selected delay is completed.
- Dual LED display: separate digital readouts provide clear operating information from the front of the device.
- Front-panel adjustment: SET, up, and down buttons provide access to protection parameters and display modes.
- Microcontroller-based control: the controller manages measurement, comparison, tripping, timing, and reconnection logic.
- Panel-ready format: the 2P body supports DIN-rail mounting, and the front logo area can be customized where required.
Protection And Selection
Choose among the confirmed 40A, 63A, and 80A versions according to the circuit design, connected load, conductor capacity, and applicable installation requirements. All three listed variants use a 2P AC 220V configuration with an AC overvoltage setting range of 130-300V and an AC undervoltage setting range of 80-210V. Final selection should be checked by a qualified electrical professional.
Setting Instructions
- Press and hold the SET button for five seconds to enter the setting state.
- Use SET to move to the required overvoltage, undervoltage, current, or timing parameter.
- Press the up or down button to change the displayed value.
- Press SET to save the selected value. Refer to the product manual before changing protection settings in an energized installation.
Display Notes
Under DC power, the supplied instructions state that only voltage is displayed and current is not shown. Parameter P15 provides three display modes:
- Mode 1 – Standard: displays parameters P1-P19.
- Mode 2 – Manual: use the up or down button to view voltage (-U-), power (-P-), current (-A-), and frequency (-H-).
- Mode 3 – Automatic: cycles through voltage, power, current, and frequency in sequence.
For parameter P19, the initial password is 112. If the lock parameter is changed and the password is reset, restore the parameter to 112 to unlock it.
Installation And Applications
GPS6-VA5 is designed for DIN-rail installation in compatible distribution assemblies that require monitored voltage and current protection. Before installation, confirm the AC 220V system, 2P wiring arrangement, rated current, conductor capacity, N/L terminal connection, protection settings, and local electrical requirements. Installation and parameter changes should be completed by qualified personnel with the circuit safely isolated.