Description
Double Delay Time Relay
GEYA Double Delay Time Relay is for gradual switching of heavy powers like heating and prevents current strokes in the main.
It has protection and monitoring of motors with integrated PTC thermistor temperature sensors. It has a range of phase loss and phase failure monitoring relays.
GEYA Double Delay Time Relay has motor monitoring for heavy starting, high switching frequency, single phase operation, high ambient temperature, and insufficient cooling.
It has solid state thyristor output, simple two wire connection, and flame-retardant housing.
GEYA Double Delay Time Relay has a professional range of single and three phase supply monitors that are feature rich for industrial and agricultural use.
The range covers phase loss/phase reversal and phase unbalance. It is available with under and over voltage, adjustable time delay, LED indications and base DIN rail mounting.
Applications
- For gradual switching of heavy powers (e.g. el.heating), prevents current
strokes in the main.
Functions
- 2x Delay ON (2 time relays in one)
- Time scale 0.1s – 10 days divided into 10 time ranges:
0.1s – 1s / 1s – 10s / 0.1min – 1min / 1min – 10min / 0.1h – 1h / 1h – 10hrs
/ 0.1 day – 1 day / 1 day – 10 days / ON / OFF.
- Times t1 and t2 are independently adjustable.
- t1 and t2 are switched on after supply voltage connection
- Relay status is indicated by LED.
- 1-MODULE, DIN rail mounting.
Technical parameters | GRT8-2T |
Function | 2x Delay ON |
Supply terminals | A1-A2 |
Voltage range | AC/DC 12-240V(50-60Hz) |
Burden | AC 0.09-3VA/DC 0.05-1.7W |
Voltage range | AC 230V(50-60Hz) |
Power input | AC max.6VA/1.9W |
Supply voltage tolerance | -15%;+10% |
Supply indication | green LED |
Time Ranges | 0.1s-10days,ON,OFF |
Time setting | potentiometer |
Time deviation | 10%-mechanical setting |
Repeat accuracy | 0.2%-set value stability |
Temperature coefficient | 0.05%/℃,at=20℃(0.05%℉,at=68℉) |
Output | 2×SPDT |
Current rating | 16A(AC1) |
Switching voltage | 250VAC/24VDC |
Min. breaking capacity DC | 500mW |
Output indication | red LED |
Mechanical life | 1×107 |
Electrical life(AC1) | 1×105 |
Reset time | max.200ms |
Operating temperature | -20℃ to+55℃(-4℉to131℉) |
Storage temperature | -35℃ to+75℃(-22℉to158℉) |
Mounting/DIN rail | Din rail EN/IEC 60715 |
Protection degree | IP40 for front panel/IP20 terminals |
Operating position | any |
Overvoltage category | III. |
Pollution degree | 2 |
Max.cable size(mm 2) | solid wire max.1×2.5or 2×1.5/with sleeve max.1×2.5(AWG 12) |
Tightening torque | 0.4Nm |
Dimensions | 90×18×64mm |
Weight | W240-82g,A230-82g |
Standards | EN 61812-1,IEC6947-5-1 |