Advanced Static Var Generators, Three Fixes, One Chassis
An advanced static var generator (ASVG) provides configurable compensation for reactive power, harmonic current and three-phase unbalance, depending on the selected model. GY-ASVG modules are available up to 150 kvar, with selected ≤45 dB low-noise and 1U rack-mount variants, plus a custom IP66 outdoor option.
Reactive + harmonics + balance
Reactive rate (≥95% harmonic)
Per module; parallel by model
Low-noise build (LN)
Premium GY-ASVG Series
A Variant for Every Room
Select functions and priorities for the chosen model at commissioning. Parallel capability depends on the model; the 220Â V 2Â kvar and 380Â V 3Â kvar LN units do not support parallel operation.
GY-ASVG
- Build
- Rack / wall module
- Voltage
- 220 V
- Capacity
- 3–75 kvar
- Highlights
- Single-phase L/N (5 kvar) or three-phase 3-/4-wire
GY-ASVG
- Build
- Rack / wall module
- Voltage
- 380 V
- Capacity
- 5–150 kvar
- Highlights
- Three-phase three-/four-wire
GY-ASVG /3L
- Build
- Three-level module
- Voltage
- 500 / 690 / 800 V
- Capacity
- 90 / 120 / 150 kvar
- Highlights
- 500 / 690 / 800 V respectively; unbalance compensation is not available on the 800 V model
GY-ASVG-PLUS
- Build
- High-spec module
- Voltage
- 220 / 400 V
- Capacity
- 37–100 kvar
- Highlights
- Neutral filtering 3× phase current; EMC Class A (RE/CE)
GY-ASVG-SiC
- Build
- SiC module
- Voltage
- 220 / 400 V
- Capacity
- 37–100 kvar
- Highlights
- T-type three-level; highest efficiency tier
GY-ASVG-LN
- Build
- Low-noise module
- Voltage
- 380 V
- Capacity
- 3 / 5 / 10 kvar
- Highlights
- ≤45 dB; built-in CT; 3 kvar does not support parallel operation
GY-ASVG-IU
- Build
- 1U slim rack
- Voltage
- 400 V
- Capacity
- 5 kvar
- Highlights
- 1U height, 9.5 kg — fits in-row server racks
GY-ASVG-IP66
- Build
- Outdoor unit
- Voltage
- 400 V
- Capacity
- 15 kvar
- Highlights
- IP66, natural cooling — pole / wall outdoor duty
GY-ASVG-cabinet
- Build
- Cabinet system
- Voltage
- Project spec
- Capacity
- Multi-module
- Highlights
- Factory-assembled and FAT-tested
Reactive compensation ≥99% (<10 ms) · harmonic compensation ≥95%, 2nd–50th (<40 ms) · unbalance after compensation ≤5% on applicable models · RS485 communication · parallel operation on supported models; LN exceptions are listed above.
Three Fixes, One Chassis
Less panel, less wiring
Combine reactive-power, 2nd–50th harmonic and three-phase-unbalance compensation in one unit where the selected model supports these functions — one point of installation, monitoring and maintenance.
A variant for every room
≤45 dB low-noise for hospitals and offices, 1U/9.5 kg for in-row racks, IP66 natural-cooling for outdoor poles — plus standard rack, wall and cabinet builds.
Priorities you control
Enable the functions supported by the selected model and set their priority order at commissioning; the unit allocates available capacity to the duty ranked first.
Right-sized from 3 kvar
From a 3 kvar low-noise unit for a clinic panel to 150 kvar modules paralleled into cabinets — one platform covers the whole range.
Questions Engineers Actually Ask
When a bus needs both reactive and harmonic correction at comparable scale, one ASVG replaces two units — saving panel space, cabling and cost, with functions coordinated on a single DSP. Choose dedicated SVG or AHF modules only when one duty dominates heavily (say, 200 A of harmonics but little reactive demand) — then a dedicated module sizes more economically.
Standard rack/wall builds suit electrical rooms. ASVG-LN (≤45 dB, built-in CT) is made for hospitals, offices and labs where noise matters; ASVG-IU (1U, 9.5 kg) slides into data-center racks; ASVG-IP66 (natural cooling) mounts outdoors on poles or walls for farm and rural distribution areas; cabinets serve centralized compensation rooms.
Yes. Reactive compensation, harmonic filtering (2nd–50th, per-order adjustable) and unbalance correction can be combined where supported by the selected model and prioritized at commissioning. The functions share available capacity; standard single-phase and 800 V models do not provide unbalance compensation.
Mostly Harmonics or Reactive Power?
If it’s almost all harmonics — or almost all reactive power — a dedicated module sizes more economically than an all-in-one.
One Unit or Two? Let the Measurement Decide
Send your load profile and power-quality measurement — our engineers will confirm whether an all-in-one ASVG or dedicated modules fit your bus best.
See ASVG at work in distribution & rural grids, medical facilities and all solutions.