Power Quality Products · ASVG

Advanced Static Var Generators, Three Fixes, One Chassis

An advanced static var generator (ASVG) provides configurable compensation for reactive power, harmonic current and three-phase unbalance, depending on the selected model. GY-ASVG modules are available up to 150 kvar, with selected ≤45 dB low-noise and 1U rack-mount variants, plus a custom IP66 outdoor option.

3-in-1

Reactive + harmonics + balance

≥99%

Reactive rate (≥95% harmonic)

3–150kvar

Per module; parallel by model

≤45dB

Low-noise build (LN)

CE
TUV
SAA
Model Lineup

A Variant for Every Room

Select functions and priorities for the chosen model at commissioning. Parallel capability depends on the model; the 220 V 2 kvar and 380 V 3 kvar LN units do not support parallel operation.

GY-ASVG

Build
Rack / wall module
Voltage
220 V
Capacity
3–75 kvar
Highlights
Single-phase L/N (5 kvar) or three-phase 3-/4-wire

GY-ASVG

Build
Rack / wall module
Voltage
380 V
Capacity
5–150 kvar
Highlights
Three-phase three-/four-wire

GY-ASVG /3L

Build
Three-level module
Voltage
500 / 690 / 800 V
Capacity
90 / 120 / 150 kvar
Highlights
500 / 690 / 800 V respectively; unbalance compensation is not available on the 800 V model

GY-ASVG-PLUS

Build
High-spec module
Voltage
220 / 400 V
Capacity
37–100 kvar
Highlights
Neutral filtering 3× phase current; EMC Class A (RE/CE)

GY-ASVG-SiC

Build
SiC module
Voltage
220 / 400 V
Capacity
37–100 kvar
Highlights
T-type three-level; highest efficiency tier

GY-ASVG-LN

Build
Low-noise module
Voltage
380 V
Capacity
3 / 5 / 10 kvar
Highlights
≤45 dB; built-in CT; 3 kvar does not support parallel operation

GY-ASVG-IU

Build
1U slim rack
Voltage
400 V
Capacity
5 kvar
Highlights
1U height, 9.5 kg — fits in-row server racks

GY-ASVG-IP66

Build
Outdoor unit
Voltage
400 V
Capacity
15 kvar
Highlights
IP66, natural cooling — pole / wall outdoor duty

GY-ASVG-cabinet

Build
Cabinet system
Voltage
Project spec
Capacity
Multi-module
Highlights
Factory-assembled and FAT-tested

Reactive compensation ≥99% (<10 ms) · harmonic compensation ≥95%, 2nd–50th (<40 ms) · unbalance after compensation ≤5% on applicable models · RS485 communication · parallel operation on supported models; LN exceptions are listed above.

Why GEYA ASVG

Three Fixes, One Chassis

Less panel, less wiring

Combine reactive-power, 2nd–50th harmonic and three-phase-unbalance compensation in one unit where the selected model supports these functions — one point of installation, monitoring and maintenance.

A variant for every room

≤45 dB low-noise for hospitals and offices, 1U/9.5 kg for in-row racks, IP66 natural-cooling for outdoor poles — plus standard rack, wall and cabinet builds.

Priorities you control

Enable the functions supported by the selected model and set their priority order at commissioning; the unit allocates available capacity to the duty ranked first.

Right-sized from 3 kvar

From a 3 kvar low-noise unit for a clinic panel to 150 kvar modules paralleled into cabinets — one platform covers the whole range.

ASVG Selection FAQ

Questions Engineers Actually Ask

When a bus needs both reactive and harmonic correction at comparable scale, one ASVG replaces two units — saving panel space, cabling and cost, with functions coordinated on a single DSP. Choose dedicated SVG or AHF modules only when one duty dominates heavily (say, 200 A of harmonics but little reactive demand) — then a dedicated module sizes more economically.

Standard rack/wall builds suit electrical rooms. ASVG-LN (≤45 dB, built-in CT) is made for hospitals, offices and labs where noise matters; ASVG-IU (1U, 9.5 kg) slides into data-center racks; ASVG-IP66 (natural cooling) mounts outdoors on poles or walls for farm and rural distribution areas; cabinets serve centralized compensation rooms.

Yes. Reactive compensation, harmonic filtering (2nd–50th, per-order adjustable) and unbalance correction can be combined where supported by the selected model and prioritized at commissioning. The functions share available capacity; standard single-phase and 800 V models do not provide unbalance compensation.

Mostly Harmonics or Reactive Power?

If it’s almost all harmonics — or almost all reactive power — a dedicated module sizes more economically than an all-in-one.

Get Started

One Unit or Two? Let the Measurement Decide

Send your load profile and power-quality measurement — our engineers will confirm whether an all-in-one ASVG or dedicated modules fit your bus best.