Power Quality Products · ASVG

Advanced Static Var Generators, Three Fixes, One Chassis

GY-ASVG combines reactive, 2nd–50th harmonic and unbalance compensation in one unit — 3–150 kvar, with 45 dB low-noise, 1U slim and IP66 outdoor builds.

3-in-1
Reactive + harmonics + balance
≥99%
Reactive rate (≥95% harmonic)
3–150kvar
Per module, unlimited parallel
≤45dB
Low-noise build (LN)
CETUVSAA
Model Lineup

A Variant for Every Room

Functions are freely selectable and re-prioritized at commissioning; all builds parallel without limit.

ModelBuildVoltageCapacityHighlights
GY-ASVGRack / wall module220 V5–75 kvarTwo-level; single-phase or three-phase
GY-ASVGRack / wall module400 V10–150 kvarThree-phase three-/four-wire
GY-ASVG /3LThree-level module500 / 690 / 800 V90–140 kvarHigher-voltage industrial buses
GY-ASVG-PLUSHigh-spec module220 / 400 V37–100 kvarNeutral filtering 3× phase current; EMC Class A (RE/CE)
GY-ASVG-SiCSiC module220 / 400 V37–100 kvarT-type three-level; highest efficiency tier
GY-ASVG-LNLow-noise module400 V3–10 kvar≤45 dB; built-in CT
GY-ASVG-IU1U slim rack400 V5 kvar1U height, 9.5 kg — fits in-row server racks
GY-ASVG-IP66Outdoor unit400 V15 kvarIP66, natural cooling — pole / wall outdoor duty
GY-ASVG-cabinetCabinet systemProject specMulti-moduleFactory-assembled and FAT-tested

Reactive compensation ≥99% (<10 ms) · harmonic compensation ≥95%, 2nd–50th (<40 ms) · unbalance after compensation ≤5% · RS485 communication · unlimited parallel operation.

Why GEYA ASVG

Three Fixes, One Chassis

Less panel, less wiring

Reactive power, 2nd–50th harmonics and phase unbalance corrected by a single unit — one point of installation, monitoring and maintenance.

A variant for every room

≤45 dB low-noise for hospitals and offices, 1U/9.5 kg for in-row racks, IP66 natural-cooling for outdoor poles — plus standard rack, wall and cabinet builds.

Priorities you control

Enable any function combination and set the priority order at commissioning; capacity allocates automatically to the duty you rank first.

Right-sized from 3 kvar

From a 3 kvar low-noise unit for a clinic panel to 150 kvar modules paralleled into cabinets — one platform covers the whole range.

ASVG Selection FAQ

Questions Engineers Actually Ask

ASVG vs installing separate SVG and AHF units — which is better?

When a bus needs both reactive and harmonic correction at comparable scale, one ASVG replaces two units — saving panel space, cabling and cost, with functions coordinated on a single DSP. Choose dedicated SVG or AHF modules only when one duty dominates heavily (say, 200 A of harmonics but little reactive demand) — then a dedicated module sizes more economically.

Which ASVG variant fits my environment?

Standard rack/wall builds suit electrical rooms. ASVG-LN (≤45 dB, built-in CT) is made for hospitals, offices and labs where noise matters; ASVG-IU (1U, 9.5 kg) slides into data-center racks; ASVG-IP66 (natural cooling) mounts outdoors on poles or walls for farm and rural distribution areas; cabinets serve centralized compensation rooms.

Can I choose which functions the ASVG performs?

Yes. Reactive compensation, harmonic filtering (2nd–50th, per-order adjustable) and unbalance correction can be enabled in any combination and re-prioritized at commissioning — the unit allocates its capacity by the priority you set, so one hardware order covers changing site needs.

One Duty Dominating the Bus?

If it's almost all harmonics — or almost all reactive power — a dedicated module sizes more economically than an all-in-one.

Get Started

One Unit or Two? Let the Measurement Decide

Send your load profile and power-quality measurement — our engineers will confirm whether an all-in-one ASVG or dedicated modules fit your bus best.

See ASVG at work in distribution & rural grids, medical facilities and all solutions.