Great Solutions · Power Quality

Power Quality Solutions,
Engineered to Your Load

From new-energy grid integration to Tier-III data centers, GEYA designs SVG, AHF and hybrid systems around your actual load profile — measured on site, simulated, and validated against IEC / grid-code targets.

The Problem

Common Power Quality Challenges

Most disturbances trace back to six root causes. We measure which ones apply to your site before recommending hardware.

Harmonic Distortion (THD)

Non-linear loads — VFDs, UPS rectifiers, LED drivers — inject harmonic currents that overheat transformers, trip breakers and distort the waveform.

Fix · AHF / Hybrid

Low Power Factor & Reactive Power

Inductive loads drag power factor down, wasting transformer capacity and triggering utility penalties on your electricity bill.

Fix · SVG

Three-Phase Imbalance

Uneven single-phase loading overloads the neutral conductor, heats motors and reduces the usable capacity of the whole system.

Fix · SVG

Voltage Flicker

Arc furnaces, welders and crushers cause rapid voltage swings — visible flicker, process instability and stress on neighboring loads.

Fix · Fast-Response SVG

Voltage Sag & Swell

Grid faults and large motor starts cause voltage dips that disrupt sensitive processes and can shut down a production line in milliseconds.

Fix · Dynamic SVG

Resonance & Capacitor Stress

Fixed capacitor banks can resonate with system harmonics, amplifying distortion and risking damage to the banks and connected equipment.

Fix · Active Filtering
By Industry

Solutions for Your Sector

Every industry stresses the grid differently. Pick your sector to see the typical issues and the GEYA products we deploy.

New Energy Grid Integration

  • Reactive power & voltage swings at the interconnection point
  • Inverter-sourced harmonics from PV / wind
  • Grid-code reactive-power support
10/35kV System SideHybrid
View Solution

AI & High-Density Data Centers

  • UPS, server and cooling-system harmonics
  • Fast-changing reactive power and phase imbalance
  • Main-bus or branch-level compensation
AHFSVGASVG
View Solution

High-end Manufacturing

  • Pulsed loads — spot welding, lithography
  • Voltage dips on sensitive semiconductor tools
  • Harmonics from large VFD populations
Fast SVGAHF
View Solution

Metallurgy & Mining

  • Severe flicker from arc / induction furnaces
  • Large reactive demand on rolling mills
  • Three-phase imbalance & harmonics
High-Side SamplingSVG / SVC Study
View Solution

Distribution / Transformer Area

  • Low PF and imbalance across mixed loads
  • Rising harmonics from EV charging & LEDs
  • Localized voltage support per district substation
LV SVGAHF
View Solution

Medical & Healthcare

  • Harmonics from MRI / CT imaging systems
  • Strict voltage stability for diagnostics
  • Uptime-critical, low-noise environment
AHFSilent SVG
View Solution
Data center power room with GEYA AHF harmonic mitigation
Deep Dive · Data Center

Keeping Tier-III Data Centers Clean & Cool

Server UPS systems draw heavily distorted, capacitive current. We pair an AHF to cancel harmonics with an SVG to correct the displacement power factor — eliminating resonance risk and freeing transformer headroom for more racks.

THD 32% → <3% PF → 0.99 Resonance eliminated
Wind farm using low-voltage GEYA compensation with high-side measurement at a 35kV interconnection
Deep Dive · New Energy

Grid-Code Compliance for Solar Energy

At a 35kV point of interconnection, GEYA uses high-side measurement to coordinate SVG or ASVG compensation on the 400V or 800V side. The low-voltage equipment supplies fast reactive support and helps the plant meet grid-operator power-factor, voltage and flicker requirements without being presented as a 35kV-rated device.

Voltage ±0.5% High-side measured Grid-code pass
How We Work

From Survey to Sign-off

A measurement-led process — we never spec hardware before we see your data.

01

Site Assessment

Review single-line diagrams, load inventory and your power-quality pain points.

02

Power Quality Measurement

On-site logging of THD, power factor, flicker and imbalance per IEC 61000.

03

Design & Simulation

Size SVG / AHF / hybrid, model the result and confirm targets before quoting.

04

Manufacturing & FAT

In-house production with a documented Factory Acceptance Test you can witness.

05

Install & Commission

On-site or remote commissioning support, with a post-install measurement report.

06

Monitoring & Support

Optional remote monitoring and three-year technical support across 50+ countries.

Choose the Right Device

Product Match

A quick map from problem to the recommended GEYA model. Mixed problems — reactive, harmonic and imbalance together — are best solved with an all-in-one ASVG.

Power Quality ProblemRecommended ProductVoltage RangeResponse
Harmonic distortion (2nd–50th)AHF · GY-AHF220V – 800VHarmonics < 40 ms
Low power factor / reactive powerSVG · GY-SVG220V – 800V *< 10 ms (transient < 50 µs)
Three-phase imbalanceSVG · GY-SVG220V – 800VReal-time, < 10 ms
Voltage flickerFast SVG · GY-SVG-PLUS SiC · GY-SVG-SiC220V – 800V *High-speed dynamic, < 10 ms
Harmonics + reactive + imbalanceASVG · GY-ASVG220V – 800V *Reactive < 10 ms / harmonic < 40 ms
Voltage deviation / sag / over-voltageAVC · GY-AVC AVC PLUS · GY-AVC-PLUS220 / 380V Stepless, contactless
PLUS: <20 ms

* GEYA SVG and ASVG units are rated for 220–800 V. For 10 kV or 35 kV systems, high-side sampling can be paired with low-side compensation. Final rating and installation point are based on site measurements and the single-line diagram. AVC Rated Power: 30–400 kVA, PLUS: up to 500 kVA

Classic Case Studies

Featured Projects

Real GEYA deployments with measured results across manufacturing, data centers, new energy and distribution networks.

Manufacturing

800 kvar SVG for an Automotive Body-Welding Shop

PF 0.63 → 0.917Penalty avoided

Impact welding loads dragged the power factor down to 0.63. An 800 kvar SVG raised it to 0.917, removing the utility power-factor penalty.

Explore More →
Data Center

AHF for Data-Center Precision-Cooling Harmonics

THDi 60% → 5%PF 0.84 → 0.96

Variable-frequency cooling compressors injected harmonics into the power room. A high-performance AHF cut current THD from 60% to 5% and lifted power factor from 0.84 to 0.96.

Explore More →
New Energy

150 A TPQC for a 309.69 kWp Rooftop PV Plant

PF 0.67 → 0.95~29% less line current

At the 400 V metering point the power factor failed grid assessment. A 150 A TPQC using high-side sampling with low-side compensation raised it from 0.67 to 0.95.

Explore More →
Petrochemical

690 V AHF for Oilfield Pump-Jack Harmonics

THDi 33.7% → 11.9%GB/T 14549 ✓

Pump-jack drives produced heavy harmonic pollution, causing mis-operation and shutdowns. A 690 V AHF brought current distortion within GB/T 14549 and the mis-trips stopped.

Explore More →
Semiconductor

AHF for Semiconductor UPS Voltage Distortion

THDu 17% → 3%No downtime

Tool harmonics pushed UPS output voltage THD to 17%, risking tool shutdown. A high-performance AHF cut it to about 3% on all three phases.

Explore More →
Distribution

TPQR for an Over-Voltage Rural PV Feeder

Voltage → 230 VImbalance fixed

Heavy rooftop PV pushed the feeder into over-voltage and three-phase imbalance, tripping inverters. A TPQR regulated voltage back to 230 V and rebalanced the phases.

Explore More →
10/35kV
System-side application · high-side sampling · low-side compensation
50+
Countries Served
<10ms
Reactive Response Time
≥98%
SiC Series Efficiency
Selection Guide

SVG, AHF or Hybrid — Which Do You Need?

Straight, engineer-to-engineer comparisons to help you spec the right power-quality device for your load and grid.

SVG vs AHF — which does my facility need?

An SVG (static var generator) corrects reactive power, power factor and three-phase imbalance with a response under 10 ms; an AHF (active harmonic filter) cancels current harmonics. Choose SVG for a low power factor or utility penalties, AHF for harmonic distortion from VFDs, UPS or rectifiers. When both occur, a TPQC handles reactive, harmonic and imbalance compensation in one cabinet.

How does an SVG compare with a conventional SVC?

A conventional SVC may combine thyristor-controlled reactors with switched capacitor banks, providing continuous or stepped reactive-power control depending on its topology. Because its output is more dependent on grid voltage and its capacitor-reactor network must be checked for harmonic resonance, performance varies with the system study. A voltage-source SVG provides symmetrical inductive and capacitive current, maintains stronger compensation during voltage dips and, in GEYA configurations, responds in under 10 ms. Final selection should consider system voltage, fault level, flicker duty and harmonic conditions.

When do I need a TPQC hybrid instead of a standalone AHF?

A standalone AHF is enough for harmonics alone. When harmonics, low power factor and three-phase imbalance occur together, a TPQC integrates all three: reactive compensation over 99%, post-compensation imbalance under 5%, 2nd–50th harmonic compensation over 95%, and neutral-line filtering up to three times phase current, with EMC Class A (RE/CE) compliance.

Are cheap single-tube IGBT units as good as module or SiC machines?

Low-price single-tube units use around 48 discrete IGBTs per 100 kvar (more failure points), deliver only 80% output at 25 °C, about 85% harmonic compensation and over 80 dB noise. GEYA IGBT-module machines use six Infineon modules, give full output at 40 °C, over 95% harmonic compensation and under 65 dB. The SiC T-type three-level series runs at a fixed 30 kHz with a lab-measured peak efficiency of 98.79% (≈98.1% at full load - about 10% lower losses than rival SiC units), in half the footprint, with full-power operation from −10 to 40 °C, three-times neutral-line filtering and 1.1× long-term overload in the smallest footprint.

Can a low-voltage SVG correct power factor on the 10kV/35kV side?

Yes. GEYA SVG and TPQC support high-side sampling with low-side compensation: a CT or multifunction meter samples the 10kV/35kV side while the unit installs on the 400V/800V side and indirectly corrects high-side power factor to meet grid assessment. Three schemes trade off accuracy, response (10 ms to about 3 s) and cost.

What makes power quality design different for an AI data center?

AI data centers combine high rack density with fast-changing GPU loads, UPS systems and variable-speed cooling. Check current harmonics, reactive power, phase balance and neutral loading at the main bus and critical branches. GEYA can apply AHF, SVG or ASVG according to measured data, the single-line diagram and load profile.

Get Started

Have a Tough Load Profile?

Send us your single-line diagram and power-quality measurements — our engineers will model your site and recommend the right SVG, AHF or hybrid solution.