Current transformer manufacturer

GEYA Current Transformers for Metering, Protection & Retrofit Panels

Choose the sensing structure around the real job: load-current measurement, residual-current monitoring, protection or retrofit installation. The range covers closed-core, split-core, circular and rectangular formats, backed by in-house engineering and production.

GCT-45 circular residual current transformer, front view
GCT-45
GCT-Y-45 circular residual current transformer, front view
GCT-Y-45
6Munits annual output
15engineering team members
Closed + splitcore structures
Round + rectangularwindow formats

Start with the sensing task

One panel may need two very different kinds of current sensing

GEYA starts CT selection with the sensing task. Choosing by enclosure shape alone can produce the wrong output or protection behavior, so define what the CT must detect before comparing window size and mounting.

01

Load-current measurement

A current-measurement CT surrounds one conductor and scales the primary current for a meter, relay, controller or monitoring device.

  • Confirm primary-current range and secondary output
  • Match accuracy, burden and connected device
  • Choose closed-core for new wiring or split-core for retrofit
02

Residual-current monitoring

A residual current transformer surrounds all live conductors of the monitored circuit and detects their vector sum for leakage or ground-fault monitoring.

  • Route all required live conductors through the same window
  • Match the CT output to the residual-current relay or monitor
  • Select window geometry around the cable set or busbar layout

Current transformer range

A practical CT portfolio for new panels and field upgrades

GEYA provides multiple core structures, window geometries and signal formats. Final ratios, accuracy and environmental limits are confirmed against the selected model datasheet.

FamilyStructureBest fitTypical series
Circular residual CT
Closed core

Compact leakage and ground-fault monitoring around cable groups

GCT-Y / GCT
Rectangular residual CT
Closed core

Wider cable bundles and busbar-oriented panel layouts

GCT-F
Retrofit residual CT
Split core

Existing installations where cable disconnection is impractical

GCTK / GCTK-N
Outdoor & waterproof CT
Application specific

Exposed installations requiring an environmental specification review

GCTHW6 / GCTHW8
Flexible & transmitter options
Signal integration

Large conductors, restricted access and monitoring-system interfaces

GCTLS / GCTBS

Selection guide

Send six inputs for a faster, more reliable CT recommendation

Send these inputs to GEYA with a photo of the conductor route and the receiving device model. That context often prevents avoidable sizing mistakes.

Define the function

Load measurement, residual-current monitoring, protection or a transmitter input.

State the electrical range

Primary current, expected leakage range where relevant, frequency and required secondary signal.

Identify the receiving device

Meter, relay, motor protector, residual-current relay, PLC or monitoring module.

Measure the conductor

Cable bundle diameter, busbar dimensions and the available installation envelope.

Choose the core structure

Closed-core for planned wiring and higher accuracy potential; split-core for retrofit access.

Confirm the environment

Indoor or outdoor use, temperature, humidity, altitude, insulation and local documentation needs.

Featured 45 mm formats

Two new closed-core residual CT housings

The GEYA GCT-Y-45 and GCT-45 both use a 45 mm circular window. The supplied selection material lists matching options up to 100 A; final ratio, output and accuracy must be confirmed for the selected version.

GCT-Y-45 closed-core residual current transformer

GCT-Y-45

Round housing with front terminal access and base mounting for residual-current monitoring assemblies.

45 mm windowClosed coreResidual monitoring
GCT-45 closed-core residual current transformer

GCT-45

Compact square housing around a circular aperture for integrated panel layouts and stable mounting.

45 mm windowClosed coreResidual monitoring
Selection note: conductor current is only one input. The CT output, connected device, accuracy class, burden and installation conditions must be checked together.
6Mannual current transformer capacity
15engineers for product and application support
ManufacturingIn-house injection-molding line
EngineeringHousing design support with quality review

Factory and supply support

From housing design to a complete CT solution

GEYA combines product engineering, in-house injection molding and a wide CT portfolio for distributors, panel builders and equipment manufacturers. This gives buyers a clearer path from application inputs to a manufacturable model.

  1. Application reviewFunction, conductor, output, accuracy and environment
  2. Model and structure selectionClosed-core, split-core, round, rectangular or flexible
  3. Housing and production planningStandard range or reviewed appearance customization
  4. Electrical and insulation checksPerformed to the confirmed model specification
  5. Sample and batch coordinationLead time and destination requirements confirmed at quotation

Quality logic

Specify the interface, then verify the exact model

GEYA reviews the CT and connected device as one measurement or protection chain. Reliable operation depends on matching the output, burden, accuracy and installation conditions across that system.

Magnetic circuit

Closed-core construction removes the installation joint and supports higher accuracy potential when wiring can pass through the aperture.

Signal matching

Ratio, output type, accuracy and burden are checked against the meter, relay, protector or controller input.

Installation fit

Window size, cable bend radius, busbar orientation, terminals and mounting space are reviewed together.

Environmental fit

Temperature, humidity, altitude, enclosure and outdoor exposure are confirmed before choosing a model.

Documentation by model

IEC, CE, RoHS and regional documentation availability is checked for the exact model and destination during quotation.

Appearance control

Country-specific appearance restrictions are reviewed before an order; an alternative housing can be proposed when required.

Applications

Built for the devices around the CT

Power meteringLoad-current signals for meters and monitoring equipment
Residual-current relayLeakage or ground-fault sensing around grouped conductors
Motor protectionCurrent feedback matched to motor protectors and relays
Panel retrofitSplit-core formats for existing cables and busbars
Smart power monitoringCT and transmitter options for data acquisition systems
Electrical fire monitoringResidual-current sensing for compatible monitoring devices

Current transformer FAQ

Questions engineers ask before selecting a CT

What does a current transformer do?

A current transformer produces a lower, usable secondary signal that represents current in a primary conductor. The connected meter, relay or controller must be compatible with that output.

What is the difference between a measurement CT and a residual current transformer?

A measurement CT normally surrounds one conductor to represent its load current. A residual current transformer surrounds all live conductors of a circuit and detects the vector sum, which is used for leakage or ground-fault monitoring.

Should I choose a closed-core or split-core current transformer?

Choose closed-core when conductors can be routed through the window during assembly and accuracy is the priority. Choose split-core when an existing conductor cannot be disconnected or retrofit time is limited.

How do I choose the CT window size?

Measure the complete cable bundle or busbar, include insulation and installation clearance, and check the available mounting envelope. The smallest window that fits correctly is usually easier to position and stabilize.

Can GEYA customize the CT housing?

Housing design support is available subject to technical, tooling, quantity and country-specific appearance review. GEYA can propose an alternative appearance when a destination-market restriction applies.

Can GEYA provide samples and compliance documents?

Sample support and model-specific documents can be reviewed during quotation. Availability, lead time and applicable IEC, CE, RoHS or regional documentation must be confirmed for the exact model and destination.

Is it safe to disconnect a CT secondary during operation?

For conventional current-output CTs, never leave the secondary open while primary current is flowing. Isolate the circuit and follow the exact product datasheet and local electrical-safety rules.

Specify the CT around your actual panel

Send the conductor dimensions, current range, output requirement and receiving device. GEYA will help narrow the structure and model before quotation.

Request a Recommendation
Contact Us

Check Out The Full Catalog