Air Circuit Breaker (ACB)

  • Rated voltage: 660(690)VAC
  • Rated current: 630-6300A
  • Rated frequency: 50HZ

All Types Geya Air Circuit Breaker (ACB)

GYDW1 series intelligent circuit breakers(hereinafter referred to as circuit breakers), are suitable for distribution networks of AC 50HZ, rated voltage up to 660V(690V)and rated current of 630A-6300A, and are used to distribute electric energy and protect the circuit and power supply equipment from overload, under-voltage, short circuit, single-phase grounding and other failures. The circuit breaker has the intelligent protection function, of which the selective protection is accurate, enhancing the power supply reliability and avoiding the unnecessary power failure. Meanwhile, it is equipped with open communication interfaces, which enable the”four remote “functions, meeting the requirements of the control center and automation system. The impulse withstand voltage of the circuit breaker at an altitude of 2, 000 meters is 8, 000V(the voltage varies with different altitudes according to relevant standards, and the maximum value is 12, 000V). When it is not equipped with any intelligent controller and sensor. the circuit breaker can be used as an isolator with the mark. The circuit breaker complies with the requirements of the standards GB140482″Low voltage switchgear and controlgear- Part 2: Low voltage circuit-breakers and EC60947-2 Low-voltage switchgear and controlgear-part 2:Circuit-breakers”etc

Why Geya Air Circuit Breaker (ACB)

  • Intelligent control function: under-voltage 0 time (timed delay) release, shunt release.
  • Multiple protection: overload (with alarm), under voltage, short circuit, single phase grounding.
  • Display function: display of setting current and voltage in each phase.
  • Self-inspection function: over-heat self-inspection and microcomputer self diagnosis.

Geya: Your Best Air Circuit Breaker (ACB) Manufacturer

Geya Air circuit breaker, also known as intelligent universal circuit breaker, is a perfect choice for the solution of power distribution system at 50 HZ, rated voltage 660V, its premier performance will protect the system and equipment from overload, under voltage, short circuit, single phase grounding and other failures. Geya air circuit breakers is designed with intelligent protection system, provides the system with enhanced power supply reliability, also, its open communication interface, meets the requirement of automation system.

At GEYA, we understand the need for keeping all devices safe, while making your business competitive. With over 10 years’ experience, GEYA products are certified CCC, CE, CB, SAA, SEMKO, TUV and ROSH industry standards.

Additionally, GEYA engineers help clients in choosing the best materials depending on the application. As a leading Air Circuit Breaker (ACB) manufacturer, GEYA adheres to a strict quality electrical process. Feel free to contact us for custom made and affordable Air Circuit Breaker (ACB).

  • Type
    Classified by mounting methods
    1. Fxed type
    2. Withdrawable type
    Classified by the numbers of poles: Three-pole, four-pole
    Classified by operation modes
    1. Power operating,
    2. Manually operated(for maintenance and repair)
  • Type of release
    Intelligent controller, under-voltage instantaneous (or time-delay)release, shunt release
  • Properties of intelligent controller
    1. Intelligent controllers are divided into: H-type (for communication), M-type(standard model), L-type
    (economical model);
    2. It has various functions, such as overload long-delay inverse time-lag, short-delay inverse time-lag, constant
    time-lag and instantaneous time-lag. Users can themselves set the protection features according to practical
    needs;
    3. Single phase grounding protection function;
    4. Display function: Display of setting current, action current and voltages in each phase (voltage display function
    should be indicated when ordering);
    5. Alarm function: Overload alarm;
    6. Self-inspection function: Overheat self-inspection and microcomputer self diagnosis;
    7. Test function: Test the operating characteristics of the controller.
  • Ambient air temperature
    The ambient working temperatures shall not be higher than + 40 c or lower than -5 c and the average value of 24h
    shall not be higher than 35℃
    Note: If user’s ambient working temperature exceed required values , they should discuss it with our company.
  • Atmospheric conditions
    The atmospheric relative humidity should not be higher than 50 when the ambient working temperature is 40 ,and should be
    comparatively higher in case of low working temperature , the maximum average relative humidity in the wettest month is 90%
    , and meanwhile the minimum average temperature of this month is+25 ,considering the condensation on product surface
    due do to temperature changes . If user’s working conditions cannot meet the above-mentioned requirements, please discuss
    with our company.
  • Protection grade: IP30
  • Class of pollution: III
  • Category of operation: Category B
  • Type of installation
    Circuit breakers with rated operating voltages of 660V(690V)or below and under-voltage release, the primary coil of power
    transformer adopts Type IV , and the installation type of auxiliary circuit and control circuit is Type III.
  • Installation conditions
    The circuit breaker should be installed as required by this Manual, with the vertical inclination of circuit breaker not more than
    5°(the inclination of mine-used circuit breaker should not exceed 15°
  • Ated current of circuit breaker
Shell grade rated current in mA

Rated current in A

2000

630/800/1000/1250/1600/2000
3200

200/2500/2900/3200

4000

3200/3600/4000

6300

4000/5000/6300