AFDD Manufacturer
All GEYA AFDDs are manufactured in strict accordance with the manufacturing process. GEYA maintains a detailed archive to ensure that no errors occur during the development, production, acceptance, or sale of AFCIs.
GEYA Electric offers over 100 products that meet the most stringent international standards, including CCC, CE, CB, SAA, SEMKO, TUV, and Rosh. In 2021, GEYA offers some of the most excellent new AFDDsystems. Check out our whole catalog to see all of the numerous AFDD we have designed, as well as their specifications.
GEYA Featured Arc Fault Detection Device
Download GEYA Products Catalog PDF
What is AFDD?
An arc-fault circuit interrupter (AFCI) also called an arc-fault detection device (AFDD),it is including arc fault breaker and afci outlet (afci receptacle).
AFDD FULL FORM
The application of AFDD-63Â afci breaker
AFDD-63 afci circuit breaker incorporating MCB, RCD, and arc fault detection module, provides protection against short circuit, overload, leakage current, an arc fault.
The Zero-sequence transformer of RCD detects leakage current, and the arc fault module detects arc fault, which enables the product to effectively disconnect the protected circuit in case of either leakage current fault or arc fault.
Nowadays the proportion of electric fire has been increasing year by year while 70% of electric fires result from arc faults. arc fault protector can effectively avoid such fires.
AFDD-63 arc fault circuit breaker applicable to both lighting distribution and power distribution system with rated current up to 63A, provides protection against arc fault, overload, short circuit, and leakage current.
Â
The application of AFDD-32 arc fault detection
AFDD-32 arc breaker incorporating MCB and arc fault detection module provides protection against short circuit. overload and arc fault. The incorporated arc fault module detects and identifies arc fault, which enables the product to effectively disconnect the protected circuit against arc fault.
AFDD-32 afci protection applicable to AC circuits with rated current up to 32A is widely used for household and similar installations.
The arc fault detection module of AFDD-32 20 amp arc fault breaker can effectively detect and identify arc faults that happened to different circuits connected in series, in parallel, and to earth resulting from disabled insulation layer due to aging, damaging, or high humidity. The product trips and disconnects a protected circuit upon detection of arc faults.
What is an ADDF3-40 15 amp arc fault breaker?
AFDD3-40 arc circuit breaker incorporating MCB, RCD, and arc fault detection module, provides protection against short circuit, overload, leakage current, an arc fault. Zero-sequence transformer of RCD detects leakage current, and arc fault module detects arc fault, which enables the product to effectively disconnect the protected circuit in case of either leakage current fault Or arc fault.
AFDD3-40 combination arc fault breaker applicable to AC circuit with rated current up to 40A provides protection against arc fault, overload, short circuit, and leakage current fault happened to branch circuits in lighting distribution and power distribution system.
The arc fault detection module of AFDD3-40 can effectively detect and identify arc faults in its protected circuit with a disabled insulation layer due to aging, damage, or high humidity. The product trips and disconnects the circuit upon detection of arc faults.
GEYA Electrical Equipment Solution
At GEYA, we recognise the need of keeping all devices secure while still keeping your organisation competitive. GEYA products are CCC, CE, CB, SAA, SEMKO, TUV, and ROSH certified, with over ten years of expertise.
GEYA engineers also assist clients in selecting the appropriate materials for their needs. GEYA follows a strict quality electrical procedure as a leading Air Circuit Breaker (ACB) manufacturer. Please get in touch with us if you require an affordable custom-design Air Circuit Breaker (ACB).